<?xml version="1.0" encoding="GBK" ?>
<rss version="2.0" xmlns:slash="http://purl.org/rss/1.0/modules/slash/" xmlns:dcterms="http://purl.org/dc/terms/">
 <channel>
  	  <title><![CDATA[午夜寂寞人的博客]]></title>
	  <link>http://wuyeujimor.blog.163.com</link>
	  <description><![CDATA[完美的心境在于珍惜拥有 ]]></description>
	  <language>zh-CN</language>
	  <pubDate>Fri, 4 Jul 2008 05:34:24 +0800</pubDate>
	  <lastBuildDate>Fri, 4 Jul 2008 05:34:24 +0800</lastBuildDate>
	  <docs>http://blogs.law.harvard.edu/tech/rss</docs>
	  <generator><![CDATA[NetEase Space]]></generator>
	  <managingEditor><![CDATA[wuyeujimor]]></managingEditor>
	  <webMaster><![CDATA[午夜寂寞人]]></webMaster>
		  <ttl>120</ttl>
	  <image>
	  	<title><![CDATA[午夜寂寞人的博客]]></title>
	  	<url>http://ava.blog.163.com/photo/Gl4Bvm5jOiu5eFsquOKg8Q==/5125377850924472827.jpg</url>
	  	<link>http://wuyeujimor.blog.163.com</link>
	  </image>
  <item>
  	<title><![CDATA[海尔冰箱传感器资料  ]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082573028689</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">海尔冰箱传感器资料</P>
<P style="TEXT-INDENT: 2em">F1&nbsp;&nbsp;&nbsp;&nbsp;冷藏蒸发器传感器短路或开路&nbsp;&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">F2&nbsp;&nbsp;&nbsp;&nbsp;环境温度传感器短路或开路&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">F3&nbsp;&nbsp;&nbsp;&nbsp;冷藏空间传感器短路或开路&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">F4&nbsp;&nbsp;&nbsp;&nbsp;冷冻温度传感器短路或开路&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">F5&nbsp;&nbsp;&nbsp;&nbsp;负7度温度传感器短路或开路</P>
<P style="TEXT-INDENT: 2em">传感器培训教材</P>
<P style="TEXT-INDENT: 2em">一、 定义及原理：</P>
<P style="TEXT-INDENT: 2em">1、一组定义：冰箱及其他家电行业普遍使用温度传感器作为感受特定部位温度并通过控制系统转换成电信号来控制系统按规定模式运行，冰箱及其他家电行业使用的传感器主要为直热式负温度系数热敏电阻器。</P>
<P style="TEXT-INDENT: 2em">①热敏电阻器定义：电阻值随其阻体温度变化而变化的热敏感半导体电阻器；热敏电阻器有正温度系数热敏电阻器、负温度系数热敏电阻器</P>
<P style="TEXT-INDENT: 2em">②负温度系数（NTC）热敏电阻器：在工作范围内，零功率电阻值随温度增加而减小的热敏电阻。</P>
<P style="TEXT-INDENT: 2em">③直热式热敏电阻器：不带加热器的热敏电阻器</P>
<P style="TEXT-INDENT: 2em">④直热式负温度系数热敏电阻器：是由电流通过热敏元件和（或）由环境温度的变化而获得其阻值变化的负温度系数热敏电阻器</P>
<P style="TEXT-INDENT: 2em">⑤绝缘型热敏电阻器：能经受试验规范所规定的绝缘电阻和耐电压试验的热敏电阻器</P>
<P style="TEXT-INDENT: 2em">2、一组特性参数：</P>
<P style="TEXT-INDENT: 2em">① 零功率电阻值：在规定温度下测量热敏电阻器的电阻值，由于电阻体内部发热引起的电阻值变化相对于总的测量误差来说可以忽略不计时测得的电阻值</P>
<P style="TEXT-INDENT: 2em">② 最大电压；在环境温下，不使热敏电阻器引起失控所允许连续施加的最大直流电压</P>
<P style="TEXT-INDENT: 2em">③ 耗散系数δ：在规定环境条件下，热敏电阻器耗散功率的变化与热敏电阻体相应温度变化之比。</P>
<P style="TEXT-INDENT: 2em">④ δ-热敏系数τ：在零功率条件下，当温度发生突变时，热敏电阻体的温度变化了始末两个温度差的63.2%所需的时间</P>
<P style="TEXT-INDENT: 2em">⑤ 绝缘电阻：在规定环境条件下，直热式热敏电阻器连在一起的引出端与外层封装面之间的直流电阻值</P>
<P style="TEXT-INDENT: 2em">⑥ 绝缘电压：在连续工作条件下，允许加到直热式热敏电阻器连在一起的引出端与外层封装面之间的最高峰电压</P>
<P style="TEXT-INDENT: 2em">⑦ 电阻-温度特性</P>
<P style="TEXT-INDENT: 2em">负温度系数热敏电阻器的电阻温度特性可用下式近似表示</P>
<P style="TEXT-INDENT: 2em">R=Ae（BT）</P>
<P style="TEXT-INDENT: 2em">R---温度为T时热敏电阻器的电阻值</P>
<P style="TEXT-INDENT: 2em">A---与热敏电阻器材料物理特性和几何尺寸有关的系数</P>
<P style="TEXT-INDENT: 2em">T---绝对温度（K）</P>
<P style="TEXT-INDENT: 2em">B---热敏系数：在两个温度下零功率电阻值的自然对数之差与两温度倒数之差的比值，B=T1*T2/（T2-T1）㏑（R1/R2）</P>
<P style="TEXT-INDENT: 2em">二、 海尔传感器特点及安装注意要点</P>
<P style="TEXT-INDENT: 2em">a) 海尔冰箱使用的传感器有两大类</P>
<P style="TEXT-INDENT: 2em">i. 冷藏用传感器：引线为白色，感温头有圆头和方头两种</P>
<P style="TEXT-INDENT: 2em">ii. 冷冻用传感器：引线为黑色，使用时感温头外部封装有黑色热缩套。</P>
<P style="TEXT-INDENT: 2em">b) 冷冻、冷藏传感器温度参数表</P>
<P style="TEXT-INDENT: 2em">冷冻传感器阻值对应表 偏差&nbsp;2% </P>
<P style="TEXT-INDENT: 2em">安装注意要点<BR>i. 各传感器感温头必须安装在设计规定的固定夹内，冷藏蒸发器传感器、-7度传感器必须紧贴到蒸发器板上，方向位置要正确，其中冷藏蒸发器传感器为方形感温头，为提高感温灵敏性感温元件是偏向一侧设置的，其对立面上有“Haier”标记，固定时必须将带“Haier”标记的对立面紧贴在蒸发器板上.<BR>ii. 传感线及感温头部分必须密封完好，无破损、折裂避免水分入侵，造成参数漂移；传感线不能被感温盘压住，应从感温盘的缺口中穿出。<BR>iii. 感温头部避免进行大于80度的弯折，目前传感器头部的感温线出线均采用直线式出线，在感温盘内不进行弯曲。<BR>。<BR>三、 传感器故障判断与维修<BR>㈠ 、感器故障判断<BR>1、 故障机理<BR>①&nbsp;&nbsp;从传感器的结构分析，感温头和传感线的密封性非常重要，外界微小的水分入侵即会造成参数的变化，因此感温头一般都做了三层密封处理，一是感温元件与焊点涂装防水绝缘材料，二层硅树脂或其他材料，三层封装头树脂帽内灌环氧树脂或玻璃封装，确保密封效果，并且对引线的材料有较高要求，必须采用耐寒线材，低温性能良好。<BR>②&nbsp;&nbsp;传感线使用耐寒线，在低温下长时间冷热循环环境下不产生裂纹，如产生裂纹水分即会沿导线渗入感温元件引起参数变化。<BR>③&nbsp;&nbsp;传感器感温元件焊点断裂变形<BR>④&nbsp;&nbsp;传感线中间断、接触不良<BR>⑤&nbsp;&nbsp;插接件接触不良<BR>2、故障表现：传感器在正常工作时一般很少发生故障，是低故障率元件，除非在安装工艺和操作未按规定要求处理、使用前感温头受剧烈撞击，引线或感温头密封有裂纹产生、超高温超高电压使其内部元件损坏。但发生故障时通过主控板的检测会进行故障提示，显示报警状态或显示F1到F5&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;F1----冷藏蒸发器传感器短路或断路<BR>F2----环境&nbsp;传感器短路或断路&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<BR>F3----冷藏空间传感器短路或断路<BR>F4----冷冻传感器短路或断路<BR>F5----负7度传感器短路或断路<BR>档位显示式冰箱故障报警图标会闪烁或某一档位闪烁，无显示冰箱传感器发生故障时会表现出某一性能故障，如不化霜、某一间室不制冷、制冷差，温度过深等。<BR>3、 故障判断方法：<BR>① 对应各型号冰箱常见故障及目前故障初步判断<BR>② 检查各插接件接触情况，检查传感器线顺序是否正确<BR>③ 检查传感器感温头固定位置方向是否正确，<BR>④ 检查感温头及引线外观有无裂纹、断裂、破裂<BR>⑤ 用万用表检测传感器电阻值，用较高精度灵敏性温度计（不能影响冰箱正常运行，与电阻实时检测）测感温头部位实际温度，检测三组温度以上，将测得值与传感器温度参数表对应检查，在考虑测试误差和传感器电阻上下限后，判断传感器的好坏。<BR>㈡、故障维修<BR>1、凡传感器本身发生故障和传感线存在裂纹的均须更换，更换时必须将接头密封良好，不能使水分入侵，同时各部位传感器不能换错，固定方向要正确，方头不能换成圆头。<BR>2、维修方法请参考更换传感器操作工艺卡片及两类故障指导卡。<BR>Haier 更换传感器操作工艺卡片 <BR>工步编码 工步名称 工步内容及要求 工艺装备<BR>01 剪断传感器连线 将需更换的传感器探头连线剪断，预留的传感器连线应保证可以连接新的传感器探头。&nbsp; 剪刀<BR>02 修剪传感器接线端 将待换传感器线接头、原冰箱传感器接线端相应错开15mm-20&nbsp;mm，并剖开外部保护线。将热缩套管套入原传感器线缆。&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 剪刀、热缩套管<BR>03 连接传感器接线端 将两跟线缆分别用接线夹套上，并用钳子夹紧（如没有接线夹可用锡焊将原传感器线缆与待换传感器线接头焊好）。用万用表检测接头是否接触良好。&nbsp; 接线端子、钳子、万用表、电烙铁<BR>04 密封传感器接线端 将热缩套管移到传感器接线端，将金属外露部位全部遮盖住。然后用热吹风将热缩套加热，直至热缩套管完全收缩及固定在位置上。&nbsp;&nbsp; 热吹风、硅胶<BR>05 固定传感器感温盘 按原固定方式固定好感温盘，保证传感器线缆弯折角度，避免线缆折裂。 螺丝刀、感温盘<BR>06 检&nbsp;&nbsp;查 使用电子数字温度计检查各传感器固定处的温度，断开传感器线插接件，用万用表检查各传感器电阻，与标准参数表判断是否正常。同时，检查冰箱的制冷情况。 电子数字温度计、万用表售后故障诊断治疗操作卡产品类别&nbsp;&nbsp;冰箱 故障名称 7B/V系列开机时间长、不停机 故障代码 <BR>一、 症状：7B/V系列开机时间长、不停机二、 原因分析：1、温度设置过低2、环境温度高&nbsp;3、传感器头放置不正确三、 <BR>四、维修工艺①7B/V系列开机时间长、不停机咨询用户接受；②冰箱位置散热是否良好，侧板后背距墙或其他器物不到10CM的为用户调整；③环境温度是否在28度以上,温度设置是否过低，指导用户使用，环境温度高时冷量散失快,相对开机时间长，温度应设置温度高一点，如6度或7度或更高④检查冷藏后背蒸发器传感器头部方向放置是否正确，方形传感器固定后头部带“Haier”字样的面应朝向门体，固定不正确的应调整正确⑤冷藏蒸发器传感器不得更换圆头传感器<BR>序号 症状 诊断 治疗 注意事项 辅助工具<BR>1． 7B/V系列开机时间长、不停机 1、温度设置过低2、环境温度高&nbsp;3、传感器头放置不正确 ①7B/V系列开机时间长、不停机咨询用户接受；②冰箱位置散热是否良好，侧板后背距墙或其他器物不到10CM的为用户调整；③环境温度是否在28度以上；温度设置是否过低，指导用户使用，温度应设置温度高一点，如6度、7度或更高④检查冷藏后背蒸发器传感器头部方向放置是否正确，方形传感器固定后头部带“Haier”字样的面应朝向门体，固定不正确的应调整正确⑤冷藏蒸发器传感器不得更换圆头传感器 <BR><BR>售后故障诊断治疗操作卡 产品类别 冰箱 故障名称 7B/V系列显示F1、F4，007系列显示F1 故障代码 <BR>一． 症状：7B/V系列显示F1、F4，007系列显示F1四、 原因分析：冷藏蒸发器传感器感温头根部开裂有裸露铜丝的现象，由于裸露铜丝现象存在，冰箱在长期工作时，会有水蒸气通过引线渗入到传感器内部&nbsp;造成传感器电阻偏小甚至接近短路，使冰箱工作偏离正常，造成显示F4或F1故障，传感器反应的不是实际冷藏蒸发器感温盘处的温度五、 <BR>判断方法及工作流程： &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;不在对应范围内四、维修工艺①将坏传感器剪掉，要求传感器引线接头错开10mm以上；②将待换传感器线接头相应错开并剖开外部保护线，将热缩套提前套入原传感器线缆；将原传感器线缆与待换传感器线接头接头用锡焊焊接良好。用万用表检测接头是否接触良好③用绝缘胶带将两接头紧密缠一圈，保证绝缘。④将热缩套套在接头上，在两端热缩管内挤入密封硅胶，稍干燥固化后用吹风将热缩套加热，使其收缩紧套在接头上。⑤按原固定方式固定好感温盘；清擦冰箱、⑥检测制冷情况，合格后完成维修<BR>序号 症状 诊断 治疗 注意事项 辅助工具<BR>1． 显示F1、F4&nbsp; 传感器或传感器线故障 更换传感器 接头要密封可靠 电子显示式温度计、万用表、螺丝刀、电烙铁、剪刀、电吹风</P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082573028689</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082573028689</guid>
    <pubDate>Wed, 5 Mar 2008 19:30:28 +0800</pubDate>
    <dcterms:modified>2008-03-05T19:30:28+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[  长虹部分空调故障代码]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082572644839</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">&nbsp; 长虹部分空调故障代码</P>
<P style="TEXT-INDENT: 2em">机型 代码 可能故障原因&nbsp;&nbsp;：&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">&nbsp;F1 室内温度传感器异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; F2 室内盘管温度传感器异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F3 室外环境温度传感器异常</P>
<P style="TEXT-INDENT: 2em">KFR-45LW/WDQ F4 室外盘管温度传感器异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; KFR-45LW/WBQ F5 压缩机排气温度传感器异常</P>
<P style="TEXT-INDENT: 2em">KFR-50LW/WBQ P1 压缩机排气温度传感器异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; P2 CT电流异常</P>
<P style="TEXT-INDENT: 2em">P4 JPM故障保护&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; P5 四通阀切换异常</P>
<P style="TEXT-INDENT: 2em">E1 室内主控板与控制面板之间通讯异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; E2 室内主控板与室外控制板之间通讯异常</P>
<P style="TEXT-INDENT: 2em">E1 主控板与面板之间通讯错误&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;E2 主控板与室外板之间通讯错误</P>
<P style="TEXT-INDENT: 2em">F1 高压开关保护&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;F2 室外风扇电机热保护器动作</P>
<P style="TEXT-INDENT: 2em">KF-75LW/WDS F3 室内风扇电机热保护器动作&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;KF-75W/W3S F4 低压开关保护</P>
<P style="TEXT-INDENT: 2em">KFR-75LW/WDES F5 逆相保护&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; KFR-120LW/WDS F6 缺相保护</P>
<P style="TEXT-INDENT: 2em">KF-120LW/WS H1 压缩机过电流保护&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;H2 压缩机堵转保护</P>
<P style="TEXT-INDENT: 2em">H3 检测不到压缩机电流&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;P1 制冷过载保护</P>
<P style="TEXT-INDENT: 2em">P2 制热过载保护&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;P3 系统异常保护</P>
<P style="TEXT-INDENT: 2em">P4 自动模式下室内温度传感器异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 无显示 制冷剂不足</P>
<P style="TEXT-INDENT: 2em">E1 控制面板测到从室内机传来的异常信息&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; E2 控制面板测到从室内机传来的异常信息</P>
<P style="TEXT-INDENT: 2em">E3 室内机测到从控制面板传来的异常信息&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; E4 室内机测到从室外机传来的异常信息</P>
<P style="TEXT-INDENT: 2em">E5 室内机测到从室外机传来的异常信息&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; E6 室外机测到从室内机传来的异常信息</P>
<P style="TEXT-INDENT: 2em">E7 室外机测到从室内机传来的异常信息&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;P1 室内风扇电机热保护器动作</P>
<P style="TEXT-INDENT: 2em">P2 室外风扇电机与压缩机热保护器动作&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;KFR-120LW/M P3 排气温度异常</P>
<P style="TEXT-INDENT: 2em">KFR-120LW/MAS P4 高压开关动作&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; KFR-71LW/M P5 逆相保护(对KFR-71LW/M是主控板上开关位置设置错误)</P>
<P style="TEXT-INDENT: 2em">P6 室内机与室外机的模式不兼?&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F1 室内机热敏电阻断路或者受损</P>
<P style="TEXT-INDENT: 2em">F2 室内机热敏电阻断路或者受损&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;F4 室外机热敏电阻断路或者受损</P>
<P style="TEXT-INDENT: 2em">F5 室外机热敏电阻断路或者受损&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F6 室外机热敏电阻断路或者受损</P>
<P style="TEXT-INDENT: 2em">F7 室外机热敏电阻断路或者受损&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;F8 室外机热敏电阻断路或者受损</P>
<P style="TEXT-INDENT: 2em">H1 压缩机电机过流&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;H2 压缩机电机堵转</P>
<P style="TEXT-INDENT: 2em">H3 压缩机电流检测异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;H6 低压开关动作</P>
<P style="TEXT-INDENT: 2em">H7 连接室内机和室外机线路或管道接错&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; E1 通讯异常</P>
<P style="TEXT-INDENT: 2em">48LW P1 制冷过载&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </P>
<P style="TEXT-INDENT: 2em">&nbsp;60系列 P2 制热过载</P>
<P style="TEXT-INDENT: 2em">51系列 P3 系统异常保护&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; P4 自动模式下室内温度传感器异常</P>
<P style="TEXT-INDENT: 2em">KFR-7ILW/D E1 通信异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp; KFR-71LW/WD P1 制冷过载</P>
<P style="TEXT-INDENT: 2em">KF-71LW P2 制热过载&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; P3 系统异常保护</P>
<P style="TEXT-INDENT: 2em">P4 自动模式室内温度传感器异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F1 高压开关保护(序号线接错或断裂,控制板上光藕或R205损坏)</P>
<P style="TEXT-INDENT: 2em">F2 室外风扇电机热保护(热保护器坏,控制板上光藕或R205损坏)</P>
<P style="TEXT-INDENT: 2em">F3 室内风扇电机热保护(热保护器坏,控制板上光藕或R205损坏)</P>
<P style="TEXT-INDENT: 2em">&nbsp; </P>
<P style="TEXT-INDENT: 2em">KFR-50LWWDFB E1 通信异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;KF-50LWWDF P1 制冷过载</P>
<P style="TEXT-INDENT: 2em">KF-60LWWDF P2 制热过载&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; KF-71LWWDF F1 高压开关保护</P>
<P style="TEXT-INDENT: 2em">KFR-51LWWDFB F2 室外风扇电机热保护&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; KFR-60LWWDFB F3 室内风扇电机热保护</P>
<P style="TEXT-INDENT: 2em">F7 温度传感器损坏或异常&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; F8 系统保护异常&nbsp; </P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082572644839</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082572644839</guid>
    <pubDate>Wed, 5 Mar 2008 19:26:44 +0800</pubDate>
    <dcterms:modified>2008-03-05T19:26:44+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[海尔水环故障代码]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082572024314</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">海尔水环故障代码</P>
<P style="TEXT-INDENT: 2em">水环热泵故障故障显示序号故障故障灯闪烁次数（嵌入机型）故障代码（暗藏机型） 1水泵排水故障10E10 </P>
<P style="TEXT-INDENT: 2em">2水流故障9E9 </P>
<P style="TEXT-INDENT: 2em">3通讯故障无E8 </P>
<P style="TEXT-INDENT: 2em">4压力故障6E6 </P>
<P style="TEXT-INDENT: 2em">5室内盘管温度2E2</P>
<P style="TEXT-INDENT: 2em">&nbsp;6室内环境温度1E1</P>
<P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082572024314</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082572024314</guid>
    <pubDate>Wed, 5 Mar 2008 19:20:24 +0800</pubDate>
    <dcterms:modified>2008-03-05T19:20:24+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[新飞故障代码]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082571626268</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">&nbsp;</P>
<P style="TEXT-INDENT: 2em">新飞空调故障代码汇总 </P>
<P style="TEXT-INDENT: 2em">23/01 25/01　 故障状态定时灯（黄色）运行灯（绿色） 室温传感器故障亮闪亮（1次/8秒） 内盘传感器故障亮闪亮（2次/8秒） 室内风机故障亮闪亮（4次/8秒） 系统异常故障闪亮（5次/8秒）亮 </P>
<P style="TEXT-INDENT: 2em">柜机01 03 031 041系列 故障状态故障代码　 室温传感器故障E1 内盘传感器故障E2 外盘传感器故障E3 杀菌功能故障E4（J系列） </P>
<P style="TEXT-INDENT: 2em">柜机02系列（46/02 50/02 58/02） 故障状态故障代码 室温传感器故障E1 内盘传感器故障E3 外盘传感器故障E2 </P>
<P style="TEXT-INDENT: 2em">柜机05系列（70/05） 故障状态故障代码 室温传感器故障E1 内盘传感器故障E2 外盘传感器故障E3 通讯故障E4（051） 电源缺相或反相E5（051</P>
<P style="TEXT-INDENT: 2em">&nbsp;</P>
<P style="TEXT-INDENT: 2em">故障类型故障状态故障原因故障代码 保护装置动作</P>
<P style="TEXT-INDENT: 2em">内机的保护装置动作过热保护E1 </P>
<P style="TEXT-INDENT: 2em">过冷保护E2 </P>
<P style="TEXT-INDENT: 2em">热敏电阻故障内机热敏电阻开路测不到内盘温度E3 </P>
<P style="TEXT-INDENT: 2em">测不到空气温度E4 压力保护　外机高低压保护E5 　　</P>
<P style="TEXT-INDENT: 2em">室外排气温感故障E6 </P>
<P style="TEXT-INDENT: 2em">3相电反相，缺相反相，缺相E7 </P>
<P style="TEXT-INDENT: 2em">热敏电阻故障外盘传感器损坏外盘传感器故障E8 </P>
<P style="TEXT-INDENT: 2em">挂机02系列04.041系列042系列05系列：故障状态定时灯（黄色）运行灯（绿色）室温传感器故障亮闪亮（1次/8秒）内盘传感器故障亮闪亮（2次/8秒）外盘传感器故障亮闪亮（3次/8秒）室内风机故障亮闪亮（6次/8秒）系统异常故障闪亮（5次/8秒）亮防冷风/除霜不影响亮1.5秒 灭0.5秒</P>
<P style="TEXT-INDENT: 2em">挂机031系列故障状态故障代码：室温传感器故障数码管显示E1</P>
<P style="TEXT-INDENT: 2em">&nbsp;内盘传感器故障数码管显示E2 </P>
<P style="TEXT-INDENT: 2em">外盘传感器故障数码管显示E3 </P>
<P style="TEXT-INDENT: 2em">室内风机故障数码管显示E4 </P>
<P style="TEXT-INDENT: 2em">系统异常故障闪亮（5次/8秒）</P>
<P style="TEXT-INDENT: 2em">
</P><P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082571626268</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082571626268</guid>
    <pubDate>Wed, 5 Mar 2008 19:16:26 +0800</pubDate>
    <dcterms:modified>2008-03-05T19:16:26+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[新科故障代码]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/275960602008257737371</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">新科故障代码</P>
<P style="TEXT-INDENT: 2em">适用新科25GW　32GW　48LW(F,B,BF)　75LW/3　120LW机型指示内容说明 </P>
<P style="TEXT-INDENT: 2em">16℃不制冷检漏,外机是否工作 </P>
<P style="TEXT-INDENT: 2em">17℃低压,缺相,相序错1缺氟或充氟过多2相位检测,电源 </P>
<P style="TEXT-INDENT: 2em">18℃电压过低电源正常自动恢复 </P>
<P style="TEXT-INDENT: 2em">19℃T1开路T1叉脚松动,T1探头坏 </P>
<P style="TEXT-INDENT: 2em">20℃T2开路T2叉脚松动,T2探头坏 </P>
<P style="TEXT-INDENT: 2em">21℃T3开路T3叉脚松动,T3探头坏</P>
<P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/275960602008257737371</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/275960602008257737371</guid>
    <pubDate>Wed, 5 Mar 2008 19:07:37 +0800</pubDate>
    <dcterms:modified>2008-03-05T19:07:37+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[扬子空调故障代码]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/275960602008257116502</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">扬子空调故障代码</P>
<P style="TEXT-INDENT: 2em">E1高压保护 </P>
<P style="TEXT-INDENT: 2em">E2防止高负荷保护 </P>
<P style="TEXT-INDENT: 2em">E3防止冻结保护 </P>
<P style="TEXT-INDENT: 2em">E4系统异常保护 </P>
<P style="TEXT-INDENT: 2em">E6室温传感器坏 </P>
<P style="TEXT-INDENT: 2em">E7管温传感器坏</P>
<P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/275960602008257116502</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/275960602008257116502</guid>
    <pubDate>Wed, 5 Mar 2008 19:01:16 +0800</pubDate>
    <dcterms:modified>2008-03-05T19:01:16+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[华宝空调器故障检修]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082563430137</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">华宝空调器故障检修</P>
<P style="TEXT-INDENT: 2em">故障现象：华宝柜机的室内机的显示屏上显示出－１到－７等数字。</P>
<P style="TEXT-INDENT: 2em">分析：当显示－１和－６时，表示室内机的电路板有问题；－３表示除霜开关或与除霜有关的电路有故障；－４表示压力开关或压力保护电路有问题；－５是指压缩机排气压力过高、压缩机过热或过流是自保停机的显示；－７是指室内外机之间的信号及室内机主板与驱动板连线有问题。</P>
<P style="TEXT-INDENT: 2em">检修实例：</P>
<P style="TEXT-INDENT: 2em">A一台型号为ＲＦ７３Ｗ３Ｂ的三匹柜机，无法启动，开机即显示“－４”。测室外机压力开关ＳＰ的常闭触点正常，再测压力继电器Ｊ３，其蓝线与紫线所接的常闭触点不通，Ｊ３另有一组闲置的常闭触点，试把蓝线与紫线改插到此组触点上，故障排除。</P>
<P style="TEXT-INDENT: 2em">B一台型号为ＫＦＲ－１２０Ｌ／Ａ３Ｓ的五匹柜机，启动五到十分钟后自保停机，显示“－５”。该空调室外机启动后能制冷，其压缩机应无问题。清洗室外机冷凝器，故障依旧。检查三相交流接触器，发觉Ｂ相不通，换之，故障排除。该空调压缩机在缺相的情况下竟能启动并运行几分钟，实属罕见，也容易引起误判，请同行注意。</P>
<P style="TEXT-INDENT: 2em">C一台华宝ＲＦ７３Ｗ３Ｂ空调开机显示－７，检查室内外机连线并无断线，拆开室内机外壳检查，发现面板与驱动板的排线被老鼠咬断两根，重新接好后，故障排除。</P>
<P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082563430137</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082563430137</guid>
    <pubDate>Wed, 5 Mar 2008 18:34:30 +0800</pubDate>
    <dcterms:modified>2008-03-05T18:34:30+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[海信柜式空调故障自诊断]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082563124682</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">适用海信海信柜式空调故障自诊断</P>
<P style="TEXT-INDENT: 2em">适用海信KFR-50LW/AD、KFR-50LW、KF-50LW、KFR-5001LW机型</P>
<P style="TEXT-INDENT: 2em">E1室内温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E2室内热交换器温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E3室外热交换器温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E4室外环境温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E5过欠压保护</P>
<P style="TEXT-INDENT: 2em">E6防冻结保护</P>
<P style="TEXT-INDENT: 2em">E7防高温保护</P>
<P style="TEXT-INDENT: 2em">E8室外环境温度过低保护</P>
<P style="TEXT-INDENT: 2em">E9过电流保护KFR-50LW/AD、KFR-50LW、KF-50LW、KFR-5001LW机型</P>
<P style="TEXT-INDENT: 2em">E1室内温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E2室内热交换器温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E3室外热交换器温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E4室外环境温度传感器不良</P>
<P style="TEXT-INDENT: 2em">E5过欠压保护</P>
<P style="TEXT-INDENT: 2em">E6防冻结保护</P>
<P style="TEXT-INDENT: 2em">E7防高温保护</P>
<P style="TEXT-INDENT: 2em">E8室外环境温度过低保护</P>
<P style="TEXT-INDENT: 2em">E9过电流保护</P>
<P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082563124682</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082563124682</guid>
    <pubDate>Wed, 5 Mar 2008 18:31:24 +0800</pubDate>
    <dcterms:modified>2008-03-05T18:31:24+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[新款格力空调代码大全]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082562858255</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">一 定频液晶型 E1：压缩机高压保护：查故障反馈线是否开路，电源电否正常，外机通风是否良好及高压管压力开关，过流保护器，强电板是否损坏，排除之可解决。 </P>
<P style="TEXT-INDENT: 2em">E2；室内防冻结保护；查室内机管温探头是否开路或插头有无插好，控制回路故障，室内风机转速是否太慢，弱电板是否损坏等，室内温度是否低于18度，排除之即可。 </P>
<P style="TEXT-INDENT: 2em">E3；压缩机低压（回气压力）过低保护，查无泄漏或氟利昂是否加足，低压开关是否损坏等 ，排除之即可解决。</P>
<P style="TEXT-INDENT: 2em">E4；压缩机排气温度过高保护，查排气温度感温探头阻值是否正常（25度时50KO）室外风机是否良好等，系统有无漏氟，排除即可解决。 </P>
<P style="TEXT-INDENT: 2em">E5；过电流（电低压）保护，检查用户家的电压控制回路故障排除即可。</P>
<P style="TEXT-INDENT: 2em">E6；静电除尘故障保护，检查高压静电除尘器是否过脏或部件故障，排除即可。 </P>
<P style="TEXT-INDENT: 2em">E6；通风故障（RF28/B系列）检查室内，外连接线有无接错，若无问题，则可能是控制板问题。 </P>
<P style="TEXT-INDENT: 2em">E7；水满保护（线控天井机）；检查水是否不能排出，排水管堵或排水电机故障。</P>
<P style="TEXT-INDENT: 2em">E7；相序保护（RF28/B系列）调整相序即可。</P>
<P style="TEXT-INDENT: 2em">H1；化霜。</P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082562858255</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082562858255</guid>
    <pubDate>Wed, 5 Mar 2008 18:28:58 +0800</pubDate>
    <dcterms:modified>2008-03-05T18:28:58+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[大金空调遥控器故障代码]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/275960602008256214518</link>
    <description><![CDATA[<div><P>室内机异常　　　　　　</P>
<P>Ａ０　外部保护装置动作　　　　　　</P>
<P>Ａ１　电路板不良　　　　</P>
<P>Ａ３　排水水位系统异常　　　　　　　　　　</P>
<P>Ａ６　风扇电动机锁定，过载　　　　　</P>
<P>Ａ７　风向摆动电机异常　　　　　　</P>
<P>Ａ９　电动膨胀阀驱动装置异常　　　　　　　　　</P>
<P>ＡＦ　排水水位异常　　　　　　　　　</P>
<P>ＡＪ　容量设定异常　　　　　　</P>
<P>Ｃ４　液体配置温度感应器异常　　　　　　　　　</P>
<P>Ｃ５　气体配管温度感应器异常　　</P>
<P>Ｃ９　吸入空气温度感应器异常　　　　</P>
<P>ＣＪ　遥控器温度感应器异常<BR></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/275960602008256214518</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/275960602008256214518</guid>
    <pubDate>Wed, 5 Mar 2008 18:21:04 +0800</pubDate>
    <dcterms:modified>2008-03-05T18:21:04+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[供电事故引发空调故障的处理]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020082561447147</link>
    <description><![CDATA[<div><P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1 ，误将380V引入220V的空调，高电压一般会烧毁控制变压器和保险丝，引发空调不工作。 （1），对于装有压敏保护电阻（该电阻形如较大的瓷片电容，并联于市电进入控制变压器初级）的，具有过压保护作用的压敏捷电阻肯定断路，而其他部件烧坏的几率不大。 （2），对于没有过压保护（无压敏电阻）的空调，在烧毁控制变压器和保险丝的同时，损坏的器件要多一些，因使用的不同和机型的不同损坏各异。用可控硅控制风扇盍的机器，槔会因过压而击穿。有时电机的启动电容也会击穿或鼓包不能使用，必须更换。 （3），如果风机电机线圈中（装有过热保护作用）的温度保险丝熔断，而电机线圈又没有短路接地的情况下，可以直接短路温度保险丝两端点。另外 在电机进线端加装保险丝，也可以起到保护作用。 </P>
<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2，三相四线制供电的380V交流线路故障，线路维修正常后，空调不能工作。 使用放置空调压缩机的商用空调，采用的是380V交流电，在电路中设有相序保护电路。空调以前使用正常，只是一次供电电路发生故障。应先检查相序，相序不正确，相序保护电路会切断电源， 防止压缩机 反转而损坏。只要将电源进线相序高速正确，空调便可以正常运转。若市电线路漏电或接地引发的故障，应检查压缩机保护器、控制变压器等。</P>
<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;3 ，供电系统电压偏低或三相不平衡，引发空调运行保护而停机。 普通空调正常使用的供电电压范围是额定正负10%，三相电压不平衡不超过正负5%。在电源供电线路合乎规定要求的情况下仍然出现运行保护，可适当提高取样电压。将取样变压器次级线圈加绕5~10圈（在注意同名端）电压增加为正确，否则反绕。意想20V交流供电市电偏低，可以在空调电源进线加装补偿电位器，减小空调启动引起的电压偏低，确保正常启动。若在同一供电线路中撞头磕脑几台空调，要同时使用时应行启动功率较大的一台，空调温度设定应有1度~2度的温差，避免同时启动，造成电压波动引起正在运行的空调保护。用电器较多 的供电电路要平衡负荷，以免控制取样电压偏低引发空调运行保护。 例如，一别墅几台春兰3P柜机，只能运行1~2台，而且每天晚上不能使用。经查是三相电压负荷不平衡，其中空调的控制取样电压和照明灯具取自同相，在用电高峰该相电压偏低造成运行中断保护。调整用电电器，灯具等负荷使感想平衡后空调能正常使用。</P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020082561447147</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020082561447147</guid>
    <pubDate>Wed, 5 Mar 2008 18:14:47 +0800</pubDate>
    <dcterms:modified>2008-03-05T18:14:47+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[什么样的女人最能勾起欲望]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020080354750142</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">最坏的做爱经验莫过于在上床之后，才发现对方不只是“口交天后”，更是一个以吸食天下小兄弟为乐的变态度女魔头。最令人恐慌兼手足无措的是，这还必须要你除掉裤子，叫你的小兄弟冒险之后方可发现真相。不过，现在有一些方法可助你在带她上床之前先监貌辨货色。什么样的女人最能勾起欲望?最坏的做爱经验莫过于在上床之后，才发现对方不只是“口交天后”，更是一个以吸食天下小兄弟为乐的变态度女魔头。最令人恐慌兼手足无措的是，这还必须要你除掉裤子，叫你的小兄弟冒险之后方可发现真相。不过，现在有一些方法可助你在带她上床之前先监貌辨货色。 </P>
<P style="TEXT-INDENT: 2em">　　　1、短发最惊喜 </P>
<P style="TEXT-INDENT: 2em">　　长发女人表示她愿意及有耐性打理麻烦的事情；但调皮的短发女人则更容易给你惊喜。</P>
<P style="TEXT-INDENT: 2em">　　头皮满载的女人要避忌；试问连自己仪表都不注重的人，你还可以对她有何期望？深啡色及红色头发的热情如火，金发女郎则最能提高床第间的趣味性。而一头卷发的美少女，猜不到吧，她们可是爱收藏皮衣器具的热门人物。 </P>
<P style="TEXT-INDENT: 2em">　　2、露胸最拚命 </P>
<P style="TEXT-INDENT: 2em">　　爱把胸部展露人前的女人表示她对性的兴趣极浓厚，不过亦有可能是对自己样貌没信心的一个敬号，所以如果你真的爱上这类型女人的话，请提防她的妆容是否过于完美，把一切在缺陷都掩盖了。 </P>
<P style="TEXT-INDENT: 2em">　　3、实臀最耐玩 </P>
<P style="TEXT-INDENT: 2em">　　结实向上翘的屁股是良好的指示——她肯定可以跟你玩通宵。相反，如果她的屁股平平坦坦，即显示她是懒虫一名，预期此姝对性无甚要求，以及会有很多男上女下的传统做爱甫士出现，她甚至极有可能无法不先去看医生才可作一些高难度的性爱技巧！ </P>
<P style="TEXT-INDENT: 2em">　　4、细脚最性感 </P>
<P style="TEXT-INDENT: 2em">　　不说不知，女人脚的大小原来跟她的盘骨是成大正比的，而盘骨则是阴道圣地大与小的最佳启示。所以跟大脚的女人上床前，请再三看看自己小兄弟的尺寸究竟能否与英伦海峡匹配，否则恐怕会落得一个吃不消的下场。&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　5、眼神最诱惑 </P>
<P style="TEXT-INDENT: 2em">　　眼神接触是自信的表现，尤其再到性，含羞答答恐怕派不上用场。如果她热爱捉住你的小兄弟睡觉的话，这绝对是一个好消息——她愿意作出任何新尝试，所以不要放弃机会跟她玩技巧。 </P>
<P style="TEXT-INDENT: 2em">　　6、嘴部运动要频密&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　请找寻热爱嘴部运动的女人（烟不离手、时常饮水、咬指甲、嗜吃如命）来作接吻对手，她们一般都在这方面技术高超，事关她们练习无间兼喜欢刺激嘴部。要是你独爱纯情的女人，恐防只能如啄木般无瘾。 </P>
<P style="TEXT-INDENT: 2em">　　7、大腿要有劲 </P>
<P style="TEXT-INDENT: 2em">　　大腿结实有劲表示她精力旺盛，她不只是会叫你把灯亮着的大胆女人，而且她在灯光下的表现一般都不会令你失望。 </P>
<P style="TEXT-INDENT: 2em">　　8、衣着时髦&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　请小心，如果她的别号叫“黑衣人”，当宽衣解带后，她过多的除了是肥肉外，更有可能是一眶眼泪。相反，衣着时髦的女人则表示刀子愿意在床上下苦功。 </P>
<P style="TEXT-INDENT: 2em">最近，“30岁的女人”又招惹男人了，进而受到批评和抨击，其中分贝比较大的声音是：30岁的美女容易红杏出墙、30岁的女人是最贱最骚的女人、是最容易被勾引的。当然这些骂声中还夹杂着咬牙切齿的申讨，真有点“草木皆兵”的氛围。　　</P>
<P style="TEXT-INDENT: 2em">　　面对一味的讨伐与责骂，我倒觉得30岁的女人并没有这么恐怖。按照莎士比亚的说法“女人啊，你的名字叫脆弱”。其实，女人永远是弱者，是被动的动物。如果把女人比作花，男人自然就是采蜜的蜂了。很简单，花总是被动地等待蜜蜂来采蜜。&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　相对与男人的风流，女人则是风骚了。为什么人们可以接受男人的风流，而不允许女人风骚呢？我们都知道，中华民族几千年的历史是一部男尊女卑的暧昧史，是绝对的男权社会。再一个，传统文化也在不停地熏陶着女人要“三从四德”，要听丈夫的话，女人就这样被愚化了。所以，唐伯虎等文化人可以四处寻花问柳，那叫做“风流才子”；而武则天玩了几个男人，最后还是要背着“荡妇”的骂名。依照男人的哲学，在性的问题上，有些“只许州官放火，不许百姓点灯”的味道。 </P>
<P style="TEXT-INDENT: 2em">　　客观地说，追求幸福生活，享受性高潮，这些都是女人的权利，如果谋求权利的途径正常，那么就受法律保障。如果谋求性福的途径不当，那就是红杏出墙了，所以要挨辱骂。女人可以风骚，但并不一定要风骚。风骚是女人的一个选项，但不一定必选。  &nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　那么，我为什么提出要尊重30岁女人的风骚权呢？有几个理由—— </P>
<P style="TEXT-INDENT: 2em">　　一、30岁的女人一样是女人，不能因为其年龄问题就歧视她们，就妖魔化。所以，将目光死死盯住30岁的女人是不公平的。 </P>
<P style="TEXT-INDENT: 2em">　　二、30岁女人的风骚是生理规律，是必然，不是空穴来风。从纯生理的角度来说：男性的性欲高峰出现在青春期到25岁之间,而女性的性高潮期是在30岁到45岁。30岁的女人比20岁、50岁的女人性欲更加强烈。美国性学实验室的科学家，曾对众多志愿者的爱猫扑/爱生活过程进行了十多年的观测和研究，科学而客观地记录了女性在性高潮的瞬间状态，发现绝大多数女人从30岁开始才真正享受性高潮。很多男人经常这样抱怨：20多岁的女人在做爱时就像死猪，不知道如何配合，也不懂技巧。这就是很好的例证。&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　三、女人的风骚和男人的风流是对等的。既然都是人，都是法律概念的自然人，至少从理论上讲，他们享有一样的法律地位和社会地位。那么，男人可以风流，女人为什么不能风骚呢？&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　四、30岁女人是不可以一个人风骚的，这种风骚的背后一定有风流的男子。骂女人风骚的一定是男人，这里就很有意思了——女人的风骚一定和男人有关，粗俗一点说，哪怕是苟合，那也得两个异性才可以进行，离开了男人的风骚是不好指责的。如果一个女人的风骚仅仅是自慰，那关别人什么事啊。 </P>
<P style="TEXT-INDENT: 2em">　　五、30岁女人的风骚，男人要负主要责任。里面有两层意思。一个意思是男人没有善待女人。30 岁的女人经历了恋爱、结婚、生子等过程，30岁的时候，孩子刚刚到了上学的年龄，这时的女人比较轻松悠闲点了，而老公正值事业期，容易忽视甚至冷落妻子，所以，这时有花心蜜嘴的男子出现，是很容易诱发出墙事件的。另一个意思是，男人喜欢在外面乱搞，比如养情人、嫖妓、搞一夜情等，女人知道了，自然心理极度不平衡，所以产生报复心理，出去勾引男人，放纵了自己</P>
<P style="TEXT-INDENT: 2em">　　在一些批评30 岁女人的言论中，我发现一个很搞笑的细节。印象特别深的是一位兄弟大开骂戒：“这30岁的女人真TMD太骚了，太贱了，我随便就可以玩几个，以后找老婆哪有安全感啊？”这位朋友得了便宜还大骂不止，真是贼喊捉贼！他可能不明白一个道理：你这样乱搞女人，势必会导致更多男人的心理失衡，并加入到一顿乱搞的队伍中，从而形成了恶性循环。按理，你只能拥有一个女人，但你搞了别人的女人，难道就不容许别人搞你的女人？其实，这位仁兄代表了天下男人的逻辑和心理：希望别人的老婆都风骚放荡，这样自己才有机会；又希望自己的老婆是圣女，不给别人一点机会。  </P>
<P style="TEXT-INDENT: 2em">　　我想，如果男人可以管住自己下面的风流根，也就不会有女人的风骚了，也不会有荡妇了。根据经济学原理，买卖是一个双方交易的行为，如果没有了买方市场，卖方市场就不复存在了。&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">　　说到女人的风骚，男人习惯一棍子打死。我觉得，女人（包括30岁的女人）的风骚，还是有所区别的，大约有这么几个层次—— </P>
<P style="TEXT-INDENT: 2em">　　第一、最低级的风骚是放荡。这种女人是一部动力强劲的欲望机器，她渴望做爱，她很主动，她饥不择食，长期处于性亢奋状态，欲壑难填，随时准备战斗，男人是她最好的食物，甚至看到雄性动物也蠢蠢欲动。这是典型的荡妇，是婊子，是骚货，是性爱永动机，你怎么骂她都不过分。第二、稍微入流一点的风骚是水性杨花。俗话说：水性流动，杨花轻飘。这种女人女人外表轻浮，眼睛顾盼含春。她的风骚写在脸上，含在眼里，但是她没有荡妇那么勇猛、那么主动、那么不知廉耻。</P>
<P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020080354750142</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020080354750142</guid>
    <pubDate>Thu, 3 Jan 2008 17:47:50 +0800</pubDate>
    <dcterms:modified>2008-01-09T10:11:29+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[何选购维护保养空调如]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020080352034103</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">&nbsp;</P>
<P style="TEXT-INDENT: 2em">一、如何选购空调器&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 空调器是一种向房间或区域直接提供经过处理的空气的设备，具有制冷、制热、除湿等功能。消费者在选购空调器时应注意以下几个问题。</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 1、选择品牌&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 家用空调器一般作为耐用消费品，在使用期间出现故障时消费者需要制造商提供售后服务，对其进行检查、维修或更换零部件。知名品牌空调器的制造商有一整套完善的质量管理体系，具有较好的产品质量保证能力，其生产的产品在性能、安全方面都有一定的保障。消费者还可以去大型的家电销售商场购买产品，其能够提供长期、优良的售后服务。&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 2、确定类型&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 家用空调器分窗式、分体挂壁式、分体落地式三大类型。窗式空调器利用房间的窗户或楼宇的空调窗进行安装，具有安装方便、维护简单的好处，但也存在噪音大，适用的环境面积小和安装不够美观的缺点。分体挂壁式和分体落地式空调器是将空调器分成室内、室外两部分，压缩机放置在室外机内，可降低室内环境的噪音，安装美观，适用的环境面积大，可选择的款式型号多样.</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 3、确定能力 .</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 选购空调器产品时，一般按住房面积每平方米200W的制冷量来计算选择空调器的能力。通常，一个10平方米左右的房间，可采用2500W制冷量的挂壁式空调器；30平方米以上的客厅或房间，需采用5000W以上制冷量的落地式空调器。但消费者在选购时还要考虑到使用空间的实际情况，如空间的格局、开放程度、太阳照射的强度、通风、人员数量等问题，如与其他地方连通在一起，或太阳照射强烈的空间应适当选购较大制冷量的空调器。 </P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 4、选择高能效比 </P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 空调器产品的表面粘贴有能源效率标识。在能源效率标识上，标有4个参数：能源效率等级、能效比、制冷量、输入功率。能源效率等级分为1～5级，最高为1级，最低为5级。在日常使用中，高能效比的意义在于使用更少的电能获得好的制冷或制热效果。高能效比的空调器节能效果非常显著。 </P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 二、如何维护、保养空调器 </P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 空调器属于季节性使用的产品，若日常使用得当，除能发挥空调器最大的功效外，还能减少故障发生率，延长其使用寿命。以下是关于正确使用、维护和保养空调器的几点方法。&nbsp;&nbsp;&nbsp;</P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 1、正确调节空调器的设定温度：使用者调节空调器的设定温度时，应根据自身对冷热的感觉、空间内的人数、空间大小等实际情况设定温度。通常在休息、睡觉等较少活动量的状态下，房间温度在25℃左右，人体会感觉到较为舒适。温度设置太低，除会使人感觉到寒冷外，由于室内、外温差较大，散热较快，致使压缩机频繁的开机和停机，缩短了空调器的使用寿命，也消耗较多能源。 </P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 2、定期对空调器进行清洁：定期拆下室内机的过滤网进行清洁，可以有效提高空调器的除尘效果，改善环境空气品质。定期清洗室外机的散热片，可有效提高其换热系数和换热效率，提高空调器的工作效率。 </P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 3、定期让专业人员检查空调器：空调器经过长期的使用后，机组内的电气线路和控制元件都会有不同程度的老化，严重的会对机组和人体造成伤害，定期让专业人员对空调器的电路进行检查，更换老化的元件，补充制冷剂，能防止元件老化对机器和人体产生危害，并能使空调器保持在良好的工作状态。 </P>
<P style="TEXT-INDENT: 2em">&nbsp; &nbsp; 4、长期不使用空调器，应做好保护措施：冬季或出外等长期不使用空调器时，应用防护罩罩着室外机部分，避免其日晒雨淋、灰尘沉积，造成日后清洗和维护的困难</P>
<P style="TEXT-INDENT: 2em"></P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020080352034103</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020080352034103</guid>
    <pubDate>Thu, 3 Jan 2008 17:20:34 +0800</pubDate>
    <dcterms:modified>2008-01-03T17:23:11+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[空调保养]]></title>	
    <link>http://wuyeujimor.blog.163.com/blog/static/2759606020073984335279</link>
    <description><![CDATA[<div><P style="TEXT-INDENT: 2em">&nbsp;</P>
<P style="TEXT-INDENT: 2em">空 调 保 养</P>
<P style="TEXT-INDENT: 2em">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 随着经济的迅速发展，人民生活水平日益提高，空调清洗已引起了广泛关注，各大电视台、报纸都在宣传：《空调一开，万只螨虫扑面来》，《空调每年都需要清洗》。空调厂家的维护说明书上也明确指出要定期进行清洗。</P>
<P style="TEXT-INDENT: 2em">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 清洗空调能节约大量电费</P>
<P style="TEXT-INDENT: 2em">近年，由于我国空调的普及，造成夏季严重缺电，部分省市频繁拉闸限电，至使一些工厂夏季无法正常生产，给国民经济造成巨大损失。空调是夏季的用电大户，据上海市统计，在夏季用电高峰期，空调用电约占全市用电的 50%。 若每个较脏的空调都及时清洗，节约用电10-30%，将根本缓解我国夏季缺电的现状。</P>
<P style="TEXT-INDENT: 2em">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 如一房间，在清洗前，降至设定温度需十分钟；而清洗后，降至设定温度仅需七分钟，则压缩机可少工作三分钟，从而节约用电 30%。目前我国的现状是：大量的空调制冷效果不好，以至延长压缩时间，浪费电力， 通过清洗可使空调恢复正常制冷效果，缩短压缩时间，节约用电10-30%。</P>
<P style="TEXT-INDENT: 2em">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 空调在无数次的重复运行中，空气中夹杂的大量尘埃和液态烟雾就会层层包裹散热片，并严重堵塞散热片之间微小空隙，影响散热片的散热，从而导致冷凝器压力升高，压缩机马达电流增大，运行时间成倍延长，耗电量显著增加。（散热片处于洁净状态时，散热良好，房间温度很快降到设定温度，压缩机自动停止工作；根据实验结果，散热片上的污垢达到 0.30毫米厚度，压缩机的工作时间将延长一倍，由下表可见空调的用电量大约增加了2.4倍。）</P>
<P style="TEXT-INDENT: 2em">清洗空调可预防空调病、皮肤病 </P>
<P style="TEXT-INDENT: 2em">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 由于空调特殊的工作方式，使其具有吸尘器一样的功效——抽进室内空气，经过蒸发器全面接触后，再吹回室内；长此以往，灰尘、污垢、细菌等积聚在空调内部，不但影响空调的制冷，还会促成螨虫的滋生；附着在室内机的细菌随送风系统吹回室内，污染室内的空气、传播疾病，严重影响人们身心健康，办公一族尤其显著！所以，人长期呆在空调房里，就会患空调综合症（头晕、乏力，免疫力下降，俗称空调病），还容易感染皮肤病。而经过清洗和消毒处理后的空调，空气更加清新，人体感觉倍加舒适。</P>
<P style="TEXT-INDENT: 2em">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 一台输入功率为 2千瓦的空调，使用了两年后，若其污垢厚度达到0.2毫米，通过清洗后可节约42%的电费，若一天使用8小时，电费为0.7元/度，一年使用5个月，则一年节约的电费为： </P>
<P style="TEXT-INDENT: 2em">2×8×30×5×0.7×0.42=706元 </P>
<P style="TEXT-INDENT: 2em">可见，用户仅花了少量清洗费，却每年节约了 700元左右的电费。 </P>
<P style="TEXT-INDENT: 2em">清洗空调可保护压缩机，延长使用寿命 </P>
<P style="TEXT-INDENT: 2em">正常情况下，压缩机排气管温度在 50度～58度，而当散热片上污垢很重时，排气管温度会升至100度～130度，压缩机冷冻油基本失去润滑作用，压缩机磨损大大加大，降低制冷效果，缩短压缩机使用寿命，甚至烧毁马达。通过清洗，散热片能回到洁净状态，排气温度回到正常，压缩机得到良好润滑，可大大改善制冷效果，延长寿命。</P>
<P style="TEXT-INDENT: 2em">本公司长期高价上门回收各种废旧物资及闲置设备回收利用价格合理、信守承诺、二手办公桌椅、家用空调、旧空调处理、冰箱、洗衣机、电脑等！</P>
<P style="TEXT-INDENT: 2em">空调旧机标准：</P>
<P style="TEXT-INDENT: 2em">大型机老式机窗机、坏机面议.好机标准：冷暖能正常使用，外表整洁无破损。旧空调,冷暖两用,新型机：窗式空调。</P>
<P style="TEXT-INDENT: 2em">品牌机：日立,夏普、三菱电机、三菱重工、海尔、春兰、松下、挂壁式空调回收价格：</P>
<P style="TEXT-INDENT: 2em">1匹新款机 300-500元/台1匹旧款机 需上门估价</P>
<P style="TEXT-INDENT: 2em">1.5匹300 -500 元/台2匹 500 -700 元/台</P>
<P style="TEXT-INDENT: 2em">柜机空调回收价格,3匹600-1000元/台5匹1000 -2000 元/</P>
<P style="TEXT-INDENT: 2em">台窗式空调回收价格,1 匹 单冷机 150元1 匹冷暖机 200-250元其它品牌窗机 需上门估价三、公平交易、按质论价 如有需求请拨打电话,021-29885301，021-27323607</P>
<P style="TEXT-INDENT: 2em">我们有专业人员上门负责免费验机，估价，拆装，运输工作；价格方面双方协商决定。 </P></div>]]></description>
	    <author><![CDATA[午夜寂寞人]]></author>
	    <comments>http://wuyeujimor.blog.163.com/blog/static/2759606020073984335279</comments>
    <slash:comments>0</slash:comments>
    <guid isPermaLink="true">http://wuyeujimor.blog.163.com/blog/static/2759606020073984335279</guid>
    <pubDate>Mon, 9 Apr 2007 08:43:35 +0800</pubDate>
    <dcterms:modified>2008-03-05T18:06:41+08:00</dcterms:modified>
  </item>    
  <item>
  	<title><![CDATA[我的密友]]></title>	
    <link></link>
    <description><![CDATA[<div>
			<a href="http://blog.163.com/blog_help/" target="_blank"><img src="http://ava.blog.163.com/photo/p92cXXW9nKVEQlNvrF8zOg==/422493940044569039.jpg" border="0" />博客小助</a>
</div>]]></description>
    <guid isPermaLink="false">http://wuyeujimor.blog.163.com/friends</guid>
    <pubDate>Tue, 1 Jan 2008 00:00:00 +0800</pubDate>
    <dcterms:modified>2008-01-01T00:00:00+08:00</dcterms:modified>
  </item>    
 </channel>
</rss>